MultiCon CMC-99
  • 9 universal inputs max.; 48 analogue inputs (0/4-20 mA or 0/1-5V or 0/2-10V) max.; 48 digital inputs max.; 24 thermocouple inputs max.; 12 RTD inputs max.; 12 counter/ flowmeter/ ratemeter inputs max.; 1 digital input 24V DC (available in standard, integrated with PS3 or PS4 power supply module)
  • Display 3.5 inch graphic TFT, 16-bit colour, 320 x 240 pixels, with touchscreen.
  • Output 8 analog (4-20 mA) max.; 16 relay (1A/250V) max.; 4 relay 5A/250V max. or 16 SSR outputs, sensor supply: 24 V DC ± 5% (200 mA max. for current inputs)
  • Internal memory 1,5 GB
  • Communication interface standard: RS-485 (Modbus RTU), 1 x USB Host; ETU version: 1 or 2 x USB Host, 1 x Ethernet 10 MB; enhanced ACM version: 2 x RS-485, 1 x RS-485/232, 1 or 2 x USB Host, 1 x Ethernet 10 MB
  Paperless Data Recorders
MultiCon CMC-141
  • Input up to 15 universal inputs; 72 analogue inputs (0/4-20 mA or 0/1-5V or 0/2-10V) max.; 72 digital inputs max.; 36 thermocouple inputs max.; 18 RTD inputs max.; 12 counter/ flowmeter/ ratemeter inputs max.; 1 digital input 24V DC (available in standard, integrated with  PS3 or PS4 power supply module)
  • Display 3.5 inch graphic TFT, 16-bit colour, 320 x 240 pixels, with touchscreen
  • Output 8 analog (4-20 mA) max.; 16 relay (1A/250V) max.; 4 relay 5A/250V max. or 16 SSR outputs, sensor supply: 24 V DC ± 5% (200 mA max. for current inputs)
  • Internal memory 1,5 GB
  • Communication interface standard: RS-485 (Modbus RTU), 1 x USB Host; ETU version: 1 or 2 x USB Host, 1 x Ethernet 10 MB; enhanced ACM version: 2 x RS-485, 1 x RS-485/232, 1 or 2 x USB Host, 1 x Ethernet 10 MB
  • Case panel mounting
  • include DAQ Manager software
  Indicators / controllers
Available categories
  • Type of Indicator and Controller: * Universal / Current and voltage/Temperature/ BCD and RS-485 * Test sets/Weight/ Accessories  
  • Digital industrial meters constitute the largest family of automation equipment, ranging from the simplest meters that are designed only to display basic parameters such as working states or physical quantities (temperature, level, pressure etc.), to more complex control units having a number of relay outputs. Depending on the type of signal measure or sensor used, the equipment can have inputs for current, voltage, millivolts or even be adapted to suit an RTD temperature sensor or thermocouple.

 
SWE-94-U meter
  • The SWE-94-U meter is equipped with one universal input: 0-20 mA, 0-10V, 0-150 mV, RTD (Pt 100/500/1000) or thermocouple (K, S, J, T, N, R, B, E). Temperature of cold ends is compensated
  Sensors / transmitters
Temperature transmitters - 85
  • - SPT-85 module is the insulated temperature Pt100, Pt500, Pt1000; TC type K, S, J, T, N, R, B, E or milivoltage input: 0-60 mV, 0-75 mV, 0-100 mV, 0-150 mVand voltage to current ,fully programmable with configuration software
 
Temperature transmitters - 61
  • The SPT-61 module is equipped with Pt 100 / Pt 500 / Pt 1000 type input with automatic recognition of 2- and 3-conductor connection.
 
Serial transmitters - 86L
  • - SPT-86L module is the insulated temperature and voltage to current in the 4-20 mA standard transmitter, and has possibility of data reading via RS-485 interface.